Lo-Lohm High Density Interface (HDI)
3-Way Solenoid Valve | 
|

 | 
The Lee Company 's High Density Interface (HDI) solenoid valve just got better by offering more flow capacity without sacrificing size and weight. Imagine the features of a large valve coupled with the superior performance of a miniature valve in one compact design.
A spike and hold voltage drive is used to achieve an extended flow and pressure range. Refer to the table below for spike actuation voltage requirements at 50 psid.
- Compact Size
- Light Weight: Less than 4.5 grams
- Operating Pressure Range: Vac - 50 psig (0-50 psid)
- Spike and Hold Voltage Drive Required
- Electrical Connection: 0.025" Sq. Pin
- Wetted Materials: PPA, PBT, 316SS, 430F SS, FKM, Epoxy
- Operating Temperature Range: 40°F to 120°F
| |
Valve Style | Configuration | Lee Part Number | Flow Capacity | Spike Actuation Voltage (VDC)
@ 50 psid | Hold Voltage (VDC) |
Plug-In | 2-Way NC
(Common Inlet) | LHDA0560245D | 450 Lohms
(39 SLPM @ 50 psid; Cv = 0.044) | 15 | 5 |
LHDA1260245D | 32 | 12 |
2-Way NO
(NO Inlet) | LHDA0560365D | 650 Lohms
(27 SLPM @ 50 psid; Cv = 0.031) | 11 | 5 |
LHDA1260365D | 25 | 12 |
Face Mount | 2-Way NC
(Common Inlet) | LHDA0570290D | 900 Lohms
(19 SLPM @ 50 psid; Cv = 0.022) | 19 | 5 |
LHDA1270290D | 45 | 12 |
The graphs below show the spike actuation voltage requirement for lower pressure operation.
Spike Actuation Voltage
vs. Differential Pressure | Flow Performance Characteristics |
| |
Plug-In Boss Detail | Face Mount Boss Detail |

VALVE BOSS MAY BE CREATED USING LEE CO CUTTING TOOL PART NO. TTTA0000180B
NOTE: SECONDARY RETENTION IS NECESSARY ON THE PLUG-IN STYLE VALVE FOR OPERATING PRESSURES ABOVE 15 PSIG. |  |
General Specifications
- Operating Pressure Range: Vac - 50 psig (0-50 psid)
- Flow Capacity (air):
- Plug-In, 2-Way NC (Common Inlet): 450 Lohms (39 SLPM @ 50 psid; CV = 0.044)
- Plug-In, 2-Way NO (NO Inlet): 650 Lohms (27 SLPM @ 50 psid; CV = 0.031)
- Face Mount, 2-Way NC (Common Inlet): 900 Lohms (19 SLPM @ 50 psid; CV = 0.022)
- Cycle life based on testing using clean dry air is 250 000 000 cycles or more. The actual cycle life may be affected by specific application parameters.
- Ambient Operating Temperature Range: 40°F-120°F (4°C-49°C). Increasing operating temperature range can limit the coil performance. Valve duty cycle must be evaluated for specific applications.
- Spike and hold voltage drive required
- Recommended Filtration: 35 microns or better
|
For more information, please send us your application information via our ASK LEE service. Or contact our application engineers in the USA at 1-800-LEE-PLUG or our representatives around the world.
Copyright 01/2013 by The Lee Company, USA
-- Trademark information --
LEE Homepage
|