Ø .312" High Pressure Flange Mount Safety Screen, 17-7PH




PERFORMANCE
LEE PART
NUMBER
LOHM RATE
(NOM.)
BURST
PRESSURE
(PSID MIN.)
COLLAPSE* PRESSURE
(PSID MIN.)
ROB** NUMBER
FSJA3120047A
40
1250
250
9.5
FSJA3120067A
40
2600
550
20
FSJA3120087A
40
3150
800
34
FSJA3120157A
40
2750
800
247


SPECIFICATIONS (NOM.)
LEE PART
NUMBER
HOLE SIZE
(IN.)
HOLE SIZE
(mM)
OPEN AREA
(IN2)
TOTAL AREA
(IN2)
NUMBER OF HOLES
FSJA3120047A
.004
100
.11
.37
9000
FSJA3120067A
.006
150
.11
.37
4000
FSJA3120087A
.008
200
.10
.37
2000
FSJA3120157A
.015
380
.15
.37
850


MATERIALS
PART
MATERIAL
SPECIFICATION
Screen
17-7PH CRES
AMS 5529
Braze
Gold Alloy
AMS 4786
* Collapse is defined as the first sign of deformation when clogged
** The ROB (Resistance to Blockage) factor is a system of rating the relative resistance to blockage of safety screens. The higher the ROB number, the more resistance to blockage.

Download a PDF file of the Product Data Sheet

For more information, please send us your application information via our ASK LEE service. Or contact our application engineers in the USA at 1-800-LEE-PLUG or our representatives around the world.
Copyright 07/2008 by The Lee Company, USA
-- Trademark information --
LEE Homepage