LHL Series Solenoid Valves

Face Mount Style

Face Mount Style - Line Drawing

(Unless otherwise specified, dimensions are in inches [mm])
(Click on drawings to enlarge)

Face Mount Style - Shaded Drawing

Swipe to the right for more table information

Part No.
(click for
drawing
)
Model Coil
Voltage
(vdc)
Operating
Pressure
Power
Consumption4
(mJ per Switch)
LOHM
Rate1
Wetted Materials2
Seal
Material
Housing Plunger
Head
Armature/
Plunger Stop
Spring
LHLA0521111H 3-Way 5 Vac-45 psig
(0-15 psid)
5.5 1100 SI PBT PPS 430 SS 316 SS
LHLA1221111H 3-Way 12 Vac-45 psig
(0-15 psid)
5.5 1100 SI PBT PPS 430 SS 316 SS
LHLA2421111H 3-Way 24 Vac-45 psig
(0-15 psid)
5.5 1100 SI PBT PPS 430 SS 316 SS
LHLA0521211H 3-Way 5 Vac-45 psig
(0-15 psid)
5.5 1100 FKM PBT PPA 430 SS 316 SS
LHLA1221211H 3-Way 12 Vac-45 psig
(0-15 psid)
5.5 1100 FKM PBT PPA 430 SS 316 SS
LHLA2421211H 3-Way 24 Vac-45 psig
(0-15 psid)
5.5 1100 FKM PBT PPA 430 SS 316 SS
LHLA0521311H 3-Way 5 Vac-45 psig
(0-15 psid)
5.5 1100 SI PBT PPS FeCr Alloy3 316 SS
LHLA1221311H 3-Way 12 Vac-45 psig
(0-15 psid)
5.5 1100 SI PBT PPS FeCr Alloy3 316 SS
LHLA2421311H 3-Way 24 Vac-45 psig
(0-15 psid)
5.5 1100 SI PBT PPS FeCr Alloy3 316 SS
LHLA0521411H 3-Way 5 Vac-45 psig
(0-15 psid)
5.5 1100 FKM PBT PPA FeCr Alloy3 316 SS
LHLA1221411H 3-Way 12 Vac-45 psig
(0-15 psid)
5.5 1100 FKM PBT PPA FeCr Alloy3 316 SS
LHLA2421411H 3-Way 24 Vac-45 psig
(0-15 psid)
5.5 1100 FKM PBT PPA FeCr Alloy3 316 SS

(1) Click here for a full description of the Lohm Laws.
(2) Click here for material information and abbreviations. Epoxy is used in the valve assembly and therefore considered a wetted material.
(3) Wetted materials are optimized for saline compatibility.
(4) Click here for complete electrical characteristics.

Pin Terminal Designation

The flow direction of a latching valve will switch to and remain in the direction indicated when a 10 ms pulse (min) is applied with the voltage and polarity as indicated in the table below. Click here for recommended driver circuit schematic. Specific pin terminal designations are shown in the drawing below.

Voltage Terminal VALVE STATE/
FLOW DIRECTION
Rated Voltage
Return
1
2
Port A – Common Flow
Rated Voltage
Return
2
1
Port B – Common Flow

Pin Terminal Designation – Face Mount Style