IEP Series Solenoid Valves

IEP Series

IEP Series - Line Drawing

(Unless otherwise specified, dimensions are in inches [mm])
(Click on drawings to enlarge)

IEP Series - Shaded Drawing

Swipe to the right for more table information

Part No.
(click for
drawing
)
SEAL
MATERIAL1
SPIKE
Voltage
(vdc)
HOLD
Voltage
(vdc)
Power @
HOLDing
VOLTAGE2
(W)
Max. SPIKE
DURATION3
(ms)
MAx. OPERATING
PRESSURE
MAX. AMBIENT
TEMPERATURE
FLOW4
psig    (bar) °F    (°C) Lohms (Cv)
IEPA1211141H FKM 12 1.6 0.25 3.8 800 (55) 120 (49) 4100 (.005)
IEPA2411141H FKM 24 3 0.25 3.8 800 (55) 120 (49) 4100 (.005)
IEPA1221141H FKM 12 1.6 0.25 2 800 (55) 275 (135) 4100 (.005)
IEPA2421141H FKM 24 3 0.25 2 800 (55) 275 (135) 4100 (.005)
IEPA1211541H FFKM 12 1.6 0.25 2 300 (21) 120 (49) 4100 (.005)
IEPA2411541H FFKM 24 3 0.25 2 300 (21) 120 (49) 4100 (.005)
IEPA1221541H FFKM 12 1.6 0.25 3.8 300 (21) 275 (135) 4100 (.005)
IEPA2421541H FFKM 24 3 0.25 3.8 300 (21) 275 (135) 4100 (.005)
IEPA1211241H EPDM 12 1.6 0.25 3.8 800 (55) 120 (49) 4100 (.005)
IEPA2411241H EPDM 24 3 0.25 3.8 800 (55) 120 (49) 4100 (.005)
IEPA1221241H EPDM 12 1.6 0.25 2 800 (55) 275 (135) 4100 (.005)
IEPA2421241H EPDM 24 3 0.25 2 800 (55) 275 (135) 4100 (.005)

(1) Wetted materials (in addition to seal): 316 stainless steel, Chrome Core® 18.
(2) Extreme environmental conditions may require higher power.
(3) Spike time is based on max. operating pressure at 70°F (21°C). Lower pressures will allow shorter spike durations. Higher temperatures will require longer spike durations.
(4) Other Lohm rates are available. Contact The Lee Company.

Chrome Core 18 is a registered trade name of Carpenter Technology Corp.

IEP SERIES SOLENOID VALVES
MORE INFO