The following specifications apply to all LSP Series solenoid valves, unless otherwise noted.

Cycle Life

The valves will typically operate across a minimum of 10 million cycles on water, depending on application conditions.

Weight

57 grams

Operating Pressure

The valves will operate within the specified pressure range when supplied with the rated voltage ± 5%.

Operating Temperature

  • Ambient operating temperature range is 40°F to 150°F (4°C to 65°C)
  • Maximum coil temperature not to exceed 180°F (82°C)
  • Increasing the operating temperature tends to limit coil performance. The valve duty cycle and energized time must be evaluated for conformance with the maximum rated operating and coil temperatures.

Storage Conditions

  • Temperature: -40°F to 175°F (-40°C to 80°C)
  • Relative humidity: 85% (max); non-condensing

Response Time

  • The typical response time is 30 ms maximum at 70°F (21°C), on air at 5 psig.
  • Response times are dependent upon system conditions, power, environment, etc. The response will typically increase as the ambient operating temperature decreases. Extended periods of valve inactivity may also have an impact on the initial response time of the valve.
  • Response times can be enhanced with the use of spike and hold drive circuits.

Electrical Characteristics

Valves are designed to operate under continuous duty at the rated voltage ±5%.

Mounting Information

Flange Mount: The valves should be mounted to a surface using #2 (M2) mounting screws. The torque specification is 10 to 15 in-oz (0.071 to 0.106 N-m). Click here for mounting details.

Filtration

Filtration of 100 microns or finer is recommended.